Bifurcation specialists

Bifurcation coronary lesions pose therapeutic problems during percutaneous coronary interventions and are associated with higher rates of periprocedural complications, as well as higher rates of intra-stent restenosis and thrombosis. Therefore, we have joined our efforts in addressing this problem, providing our customers with the most advanced technology for this market.

bioss-lim-C

Novel coronary stent for bifurcation formed by a chromium-Cobalt platform with biodegradable polymer and sirolimus. With an exclusive design that guarantees a safe and effective implantation avoiding the occlusion of SB and the displacement of the carina.

Innovative stent system for fork:

  • Material of the stent platform: CROMO-COBALTO L605
  • Stent coverage: HYDROPHY
  • RMI: INSURANCESTRUS THICKNESS: 0.07MM
  • Antiproliferative agent: SIROLIMUS
  • Radical force: HIGH
  • Push and seaworthiness: EXCELLENT
  • Inflation and deflation time: SHORT
  • Proximal diameter of the stent: 2F (0.65 MM)
  • Distal diameter of the stent: 2.7F (0.90MM)
  • Compatible with guides: MAX 0.014 “
  • Compatible with guide catheter: 5f (0.056 “)
  • Nominal pressure: 10atm
  • Release system: FAST EXCHANGE
  • Length of the release system: 140CM
  • Pre-assembled in ball: BOTTLE
alex plus

Chromium-Cobalt Stent with biodegradable polymer of sirolimus with “open cell” design for all injuries including bifurcation, as it facilitates access to the SB.

Coronary stent of chromium-cobalt and sirolimus with low profile and high flexibility:

  • Material of the stent platform: CROMO-COBALTO L605
  • Polymer: BIODEGRADABLE
  • Antiproliferative agent: SIROLIMUS
  • Proximal diameter of the stent: 2.00 MM (4.50 MM)
  • Nominal stent length: 8MM – 40MM
  • Strut thickness: 0.07MM
  • Radiopacity: EXCELLENT
  • Ferromagnetism: NONE
  • RMI: INSURANCE
  • Compatible with guides: MAX 0.014 “
  • Compatible with guide catheter: 5F (0.056 “)
  • Radial force: HIGH
  • Push and seaworthiness: EXCELLENT
  • Mounted stent profile: 0.034 “
  • Proximal diameter: 1.8F / 0.60MM
  • Distal diameter: 2.5F / 0.84 MM
  • Nominal pressure: 8 ATM
  • Release system: FAST EXCHANGE
  • Length of the release system: 140 CM
bottle

The only balloon catheter on the market designed specifically for angioplasty of bifurcation lesions and vessels with high mismatch. Its innovative design, composed of two diameters, allows adaptation to the natural morphology of the vessel without modifying its original anatomy. It allows precise placement thanks to the three radiopaque markers it has.

Bottle angioplasty catheter:

  • Material of the ball: NYLON
  • Nominal pressureL: 10 BARS
  • Maximum pressure: 16 BARS
  • Coated catheter: HYDROPHILIC
  • Diameter of proximal body: 2F (0.65mm)
  • Diameter of the distal body: 2.7F (0.90mm)
  • Push and traceability: EXCELLENT
  • Inflation and deflation time: VERY SHORT
  • Supported guide: MAX. 0.014
  • Catheter length: 140 CM.
  • Use 0.14 “guide.
  • Use with minimum 5-gauge catheter.
  • Lower ball diameters: FROM 2.5 to 3.75 mm.
  • Upper diameters of the balloon: FROM 2.75 to 4.5 mm.
  • Length of the ball: FROM 10 TO 23 M
riverCTO

The solution to chronic occlusion by balloon catheter with the smallest diameters in the market.

Cattle ball cone:

  • Material of the ball: NYLON
  • Nominal pressure: 8 BARS
  • Maximum pressure: 18 BARS
  • Coated catheter: HYDROPHILIC
  • Tip profile: 0.016 “
  • Push and traceability: EXCELLENT
  • Inflation and deflation time: VERY SHORT
  • Supported guide: MAX. 0.014 “
  • Catheter length: 140 CM.
  • Use with 0.14 “guide.
  • Use with minimum 5-gauge catheter.
  • Balloon diameter: FROM 0.75 to 1.25mm.
  • Length of the ball: FROM 10 TO 40 MM
valver

Currently, the indication of balloon valvuloplasty in patients with aortic stenosis of degenerative etiology, has limited utility and serves as a bridge for definitive treatment with our balloon being the best choice because of its diversity of measures

Catheters balloon for valvuloplasty:

  • Nominal pressure: DE 2 to 2.5 ATM
  • Available balloon diameters: FROM 15 MM to 35 MM and FROM 5 to 15 MM (in pediatrics)
  • Available balloon lengths: 25/40/45/50/60 MM and 20/25/30/40 MM (inpediatric)
  • Catheter lengths available: 70 CM (in pediatrics) and 110 CM (adults)
  • Radiopaque markings in distal and proximal part of the balloon.
  • Equipped with a waist for positioning.
  • High navigability

QUALITY POLITICS
PRODUCTS
LOGSA STUDIES

SERVICE TO THE PROFESSIONAL WITH THE MOST NOVEL PRODUCTS IN THE MARKET